Skip to main content
Advanced Search
Search Terms
Content Type

Exact Matches
Tag Searches
Date Options
Updated after
Updated before
Created after
Created before

Search Results

230 total results found

Grease separators

Sala Kitchen Maintenance

Operation Manual GS1850-F Grease Separator

New Sala Kitchen Routine

Sala Kitchen

Time Activity Comment 6:30 Sala Chores 6:30 Porridge Making 6:30 KA Breakfast ? 4 Islands Table Oak Panel open 7:15 Breakfast Monk washing up in monk area (nun the same) 8:15 Cooking  2 Is...

Disabled Toilet

Sala

The alarm is raised when a red cord is pulled in one of the disabled toilets. The alarm goes off in the whole sala.  The red indication light next to the fire panel comes on to indicate which toilet is in emergency. The rescuer goes to the toilet and can pr...

Dimmer lights

Sala Electrical System

Only in monks' and nuns' eating areas.  The dimmer light (white button) has a memory, so if you turn it on with a short hold it will automatically set itself to the previous brightness. Press and hold to set the strength of the lights.  To dimming up or dow...

Skylights

Sala

The Sala skylights are the only ones with Blinds The switch panels for the blinds and windows are in the servery area near to kitchen lobby.  There are separate panels for either side of the main chamber (enlarge the photo to see this).  Press a switch once...

Light sensors with timer

Sala Electrical System

Pendant light outside the main sala porch and lights in the sala lobby (shoe area) (2 X LED, 2 X pendant lights) These lights are controlled by two sensors: 1) An analogue timer  (this takes priority; so the lights can be automatically programmed to turn off...

PIR lights (motion sensors)

Sala Electrical System

No manual light switch in according areas  -disabled toilets (timer inside toilets besides ceiling light) -all toilets (timer in the toilet besides ceiling light) -monk's store room by the coat & shoes hall way -nun's pigeon area (timer besides ceiling lig...

Systems operation - Eleonora's notes

Sala

The training notes document is still in progress: to view and comment in real time, please refer to the Google Drive document: 6s Site training notes – EM I have added to the document some comments (highlighted in yellow) and I have highlighted in pink the p...

Audio Equipment Manuals & Documentation

Sala

Microphones AKG D5 S Dynamic Microphone AKG D5 S Microphone Quickstart Guide: AKG_D5S_D5LX_Quickstart_Guide.pdf AKG D5 S Microphone Manual: AKG_D5_D5S_Manual.pdf AKG D5 S Microphone Service Documentation: AKG_D5_D5S_Service_Documentation.pdf AKG D5 ...

Sala Audio

Phase 6s Transition Subsections

Power outage backup

Sala Kitchen Appliances

Wall sockets backup  Washing up stations under the sinks Outside the kitchen store on left wall and right cupboard             Power outage generator backup How to Start a Generator move generator to the back of the kitchen (never run genera...

Power switches for cooking appliances

Sala Kitchen Appliances

Location   wall facing the kitchen store   

CO2 Meter

Sala Ventilation

SenseAir is a high-quality CO2 meter that measures CO2 as well as temperature and relative humidity to monitor the indoor climate. It  comes with a power adapter and does not work on batteries. Why do we measure CO2? CO2 is often measured in indoor envir...

Backup Generator

Sala Electrical System

The petrol generator is in the Main Electrical Room on the side of the workshop. What is powered in the Kitchen Sockets in the back wall (washing up) Heat Pump ? Hot Water ? Procedure Move it with its cable outside the Kitchen Plug the cables and ...

Electrical Installation

Sala Electrical System

Nomenclature Every switch and sockets are labeled:  BS/xx/xx  eg. DB/GF/01 = Distribution board, Ground Floor, 01 is by the monks eating room DB/FF/xx = Distribution board, First Floor, xx "DB/GF/01/2L3" DB (Distribution Board)/GF (Ground Floor)/01 (Dist...

Plumbing

Sala

Valves Hot Water in the Kitchen All the sinks have mixer valves below the basin which mean the temperature should never be scolding. The boiler is heated by the Air Source Heat pump which is outside the kitchen. From the boiler the hot water goes to eith...

Emergency Lights

Sala Electrical System

Next to Breaker Switch Need key to rock switch These need to be tested once a year by.a professional. If the green light is blinking it is probably due to a fault. These have 2 power supplies.  When the professional does the test they kill the permanen...

Community Training

Phase 6s Transition Subsections

Monday 9th Dec On Monday the 9th of December, tours will be happening to show how to use the new building area. You are welcome to join any of them.  Time Persons in Charge Area 8:30–9:30 Tan Passado + Aj. Ruciro Main Building 9:30-10...

Sala Floor Plan

Sala

Sala Floor Plan close up.jpg Sala Floor Plan including Outbuildings.jpg Sala Upper Floor Plan.jpg Sala Outbuildings FloorPlan BW.jpg

Changing Light Bulbs

Sala Electrical System

Most of them in the building are integral and cannot be changed by us. In the main chamber, the ones embedded in the shelf pointing downwards, and the ones on top of the shelf can be changed by us. Every light bulb has a driver, so if you change a bulb and i...